文章摘要
资丹,王福军,陶然,侯亚康.边界层网格尺度对泵站流场计算结果影响研究[J].水利学报,2016,47(2):139-149
边界层网格尺度对泵站流场计算结果影响研究
Research for impacts of boundary layer grid scale on flow field simulation results in pumping station
投稿时间:2015-04-29  
DOI:10.13243/j.cnki.slxb.20150495
中文关键词: 泵站  流场计算  边界层网格尺度  漩涡
英文关键词: pumping station  flow field simulation  boundary layer grid scale  vortex
基金项目:国家自然科学基金项目(51139007);国家科技支撑计划项目(2015BAD20B01)
作者单位E-mail
资丹 中国农业大学水利与土木工程学院, 北京 100083  
王福军 中国农业大学水利与土木工程学院, 北京 100083
北京市供水管网系统安全与节能工程技术研究中心, 北京 100083 
wangfj@cau.edu.cn 
陶然 中国农业大学水利与土木工程学院, 北京 100083  
侯亚康 中国农业大学水利与土木工程学院, 北京 100083  
摘要点击次数: 2564
全文下载次数: 73
中文摘要:
      壁面处的y+值是体现壁面边界层网格尺度的主要参数,对泵站流场数值计算结果有重要影响。为明确不同计算目标对y+的依赖性,以一泵站为研究对象,在网格数量无关性检查的基础上,从网格划分难易程度、数值计算精度和效率方面提出3种网格划分方案:全局非结构网格方案,指定边界层高度的全局非结构网格方案,以及指定边界层高度的分块结构网格方案,对应的y+值分别为10~2 000、10~1 000、10~500。方案二与方案三在模拟得到的流速分布均匀度方面几乎没有差别,涡量场的漩涡数量、涡量值和漩涡核心区分布位置也非常接近,而方案一则与之相差较大。研究发现,当只需了解泵站宏观水力性能时,可采用简单易行的方案一所对应的网格方案,y+范围可适当放宽到0~2 000;当要预测进水部分流场的流动特性,特别是漩涡分布特性时,需确保y+位于1 000以内,可采用方案二的网格方案;若对进水流场进行详细研究,或者进行除涡装置的研究时,则需使得整个计算域的y+满足30~500的要求,即采用方案三的网格方案。
英文摘要:
      The y+ value on a wall is a primary parameter of boundary layer grid scale, and has important influence on the flow field numerical simulation for pumping stations. In order to clarify the requirements of y+ for different simulation objectives, a realistic pumping station was adopted and evaluated. Considering of meshing difficulty, numerical computation accuracy and efficiency, three kinds of numerical grid schemes were put forward based on the grid independence analysis. The three schemes were named global unstructured grid, global unstructured grid with specified boundary layer height, and block structure grid with specified boundary layer, respectively, which result in the corresponding value of y + 10~2000, 10~1000, 10~500. The results showed little difference in velocity distribution uniformity between scheme 2 and scheme 3. However, scheme 1 was comparatively large difference with the other two schemes. If the macro hydraulic performance of pump station is the main concern, a simple and easy grid scheme (scheme 1) could meet the satisfaction, y+ value could be relaxed appropriately to 0~2000. If the vortex distribution in flow field is the main concern, y+ should be less than 1000, the scheme 2 of gridding should be adopted. If the detailed flow structures, or vortex elimination devices become the main concern, y+ must be within 30~500,and the scheme 3 is the best choice.