Page 126 - 2022年第53卷第5期
P. 126
表 2 参数灵敏度计算结果一览表
-
参数 变化范围?% 抽水井温度?℃ S 第Ⅲ承压含水层 Cl浓度?(mg?L) S
原值 0 20.5970 0 155.8000 0
50 20.5938 0.0003 155.6867 0.0015
20 20.6350 0.0092 155.9510 0.0048
K xx (K yy )
- 20 20.6346 0.0091 156.1624 0.0116
- 50 20.6873 0.0088 155.9872 0.0024
50 20.6031 0.0006 155.8398 0.0005
20 20.6236 0.0065 156.1188 0.0102
K zz
- 20 20.6200 0.0056 156.1046 0.0098
- 50 20.6239 0.0026 155.9901 0.0024
50 20.6084 0.0011 155.8760 0.0010
20 20.5969 0.0000 155.7301 0.0022
S s
- 20 20.6160 0.0046 156.0335 0.0075
- 50 20.6210 0.0023 155.5142 0.0037
50 20.3351 0.0254 155.9472 0.0019
20 20.4711 0.0306 155.6690 0.0042
β L
- 20 20.8217 0.0545 155.9640 0.0053
- 50 21.6657 0.1038 155.8706 0.0009
50 20.6098 0.0012 155.9231 0.0016
20 20.5930 0.0010 155.7393 0.0019
β T
- 20 20.6172 0.0049 155.7864 0.0004
- 50 20.6054 0.0008 155.6307 0.0022
50 20.4220 0.0170 155.9741 0.0022
20 20.5765 0.0050 155.7617 0.0012
c s
- 20 20.6596 0.0152 155.6115 0.0060
- 50 20.8688 0.0264 155.7046 0.0012
50 20.5587 0.0037 155.8965 0.0012
20 20.5940 0.0007 155.6158 0.0059
λ p
- 20 20.5850 0.0029 155.5738 0.0073
- 50 20.6962 0.0096 156.0629 0.0034
50 20.6043 0.0007 152.3039 0.0449
20 20.6128 0.0038 154.0463 0.0563
α L
- 20 20.6232 0.0064 158.6047 0.0900
- 50 20.6255 0.0028 165.5270 0.1249
50 20.6113 0.0014 166.5632 0.1382
20 20.6118 0.0036 160.3710 0.1467
α T
- 20 20.6129 0.0039 147.3284 0.2719
- 50 20.6133 0.0016 143.4690 0.1583
50 20.4854 0.0108 149.0845 0.0862
20 20.5661 0.0075 152.7718 0.0972
n
- 20 20.6297 0.0079 160.0056 0.1350
- 50 20.7060 0.0106 171.7360 0.2046
由计算结果可知:对于抽水井热贯通影响纵向热弥散度最大,热容量次之。对于第Ⅲ承压含水层
-
Cl浓度影响纵向弥散度最大,孔隙度次之。本次研究纵向热弥散度、热容量参数通过现场试验反演获
得,孔隙度根据室内土工试验获得,确保了模型的可靠性,而由于模型识别验证阶段是时间较短,第
-
Ⅲ承压含水层 Cl浓度反应不明显,因此各层溶质弥散度参考前期研究成果,以确保模型能客观反映
-
含水层 Cl浓度的变化特征。
— 6 2 —
6